Product Details:
Minimum Order Quantity | 1 Unit |
Brand | CVG |
Model | CVG-DMTR |
Application | Industrial |
It operates on the principle of variable area; the fluid in the metal tube raises the float
in the taper tube increasing the area of passage of fluid. By a magnetic coupling the
inner float movement through a series of linkages and counter weight. The tube and
the float combination determines the flowrate.
the inner float magnetic field is detected by the high sensitive magnetic field detection
sensor ,enable us to show the digital readout.
as such this flowmeter does not require any electrical connection, since it operates on
battery. This got an inbuilt two wire transmitter just provide 24 vdc. And take 4 – 20
ma signal.
benefits of cvg’s variable area flow meters:-
local indication without the need for auxiliary power.
minimum pressure losses.
easy to read.
accurate measurement even at higher flow
(150 m3/hr).
suitable for low flow (10 lph)
default inbuilt transmitter of 4 – 20 ma (loop
no movement assembly reducing the maintenance.
maximum flow and pressure loss
line
20 °c. Water
size
flow m3/hr
nb
15 0. 2 – 1. 2 6 – 35 200 – 225
20 0. 4 – 2. 0 8 – 60 220 – 230
25 1 – 5 30 – 150 200 – 270
40 2. 5 – 10 70 – 300 200 – 250
50 3. 5 – 17 100 – 500 225 – 260
65 6 – 30 200 – 900 225 – 240
80 10 – 45 300 – 1200 225 – 260
100 20 – 100 600 – 3000 350 – 700
125 30 – 120 900 – 4000 300 – 850
150 30 – 150 900 – 4500 350 – 950
0 °c. 1 atm
air flow
The mentioned prices are approx price & it may vary as per your requirement because it requires customization in product.
nm3/hr
approx. Pressure loss
mm wc
It operates on the principle of variable area; the fluid in the metal tube raises the float
In the taper tube increasing the area of passage of fluid. By a magnetic coupling the
Inner float movement through a series of linkages and counter weight. The tube and
The float combination determines the flowrate.
The inner float magnetic field is detected by the high sensitive magnetic field detection
Sensor ,enable us to show the digital readout.
As such this flowmeter does not require any electrical connection, since it operates on
Battery. This got an inbuilt two wire transmitter just provide 24 vdc. And take 4 – 20
Ma signal.
Benefits Of CVG’s Variable Area Flow Meters:-
Local indication without the need for auxiliary power.
Minimum pressure losses.
Easy to read.
Accurate measurement even at higher flow
(150 m3/hr).
Suitable for low flow (10 LPH)
Default inbuilt transmitter of 4 – 20 mA (Loop
No movement assembly reducing the maintenance.
Maximum Flow And Pressure Loss
Line
20 °C. water
size
flow m3/hr
NB
15 0.2 – 1.2 6 – 35 200 – 225
20 0.4 – 2.0 8 – 60 220 – 230
25 1 – 5 30 – 150 200 – 270
40 2.5 – 10 70 – 300 200 – 250
50 3.5 – 17 100 – 500 225 – 260
65 6 – 30 200 – 900 225 – 240
80 10 – 45 300 – 1200 225 – 260
100 20 – 100 600 – 3000 350 – 700
125 30 – 120 900 – 4000 300 – 850
150 30 – 150 900 – 4500 350 – 950
0 °C. 1 atm
Air flow
Nm3/hr
Approx. Pressure Loss
mm WC
The mentioned prices are approx price & it may vary as per your requirement because it requires customization in product.
The mentioned prices are approx price & it may vary as per your requirement because it requires customization in product.
We have more than 14 years of experience in manufacturing, exporting and supplying supreme quality Industrial Electromagnetic Flow Meters. The provided wire meters are manufactured by utilizing high quality raw materials and employing pioneering techniques. These meters are highly demanded in oil refineries for measuring temperature, pressure and flow to control complex & simple processes. Our quality controllers test the provided meters on several parameters before delivering at clients premises. Further, these Industrial Electromagnetic Flow Meters can be purchased from us at market-competitive prices.
Features:
Technical Details:
Line Size | 15 NB to 300 NB/350NB-2000NB insurtion type |
Power Supply | 24 VDC |
Accuracy | ± 1% of flow rate, Option: ±0.5% on request |
Flow Range | 0.5m/s to 10m/s |
Minimum Conductivity | 5μs/cm (micro Siemens/centimeter) |
Lining | PTFE, Neoprene EPDM. |
Process Temperature | Up to 80O°C for Neoprene, Up to 150OC for PTFE |
Electrodes | SS316, HastalloyC, Titanium, Monel |
Protection | IP67; Optional: IP68, Flameproof |
Connection | Flanged to ASA/BS/DIN/JIS |
Additional Information:
We have more than 14 years of experience in manufacturing, exporting and supplying supreme quality Industrial Electromagnetic Flow Meters. The provided wire meters are manufactured by utilizing high quality raw materials and employing pioneering techniques. These meters are highly demanded in oil refineries for measuring temperature, pressure and flow to control complex & simple processes. Our quality controllers test the provided meters on several parameters before delivering at clients premises. Further, these Industrial Electromagnetic Flow Meters can be purchased from us at market-competitive prices.
Features:
Technical Details:
Line Size | 15 NB to 300 NB/350NB-2000NB insurtion type |
Power Supply | 24 VDC |
Accuracy | ± 1% of flow rate, Option: ±0.5% on request |
Flow Range | 0.5m/s to 10m/s |
Minimum Conductivity | 5μs/cm (micro Siemens/centimeter) |
Lining | PTFE, Neoprene EPDM. |
Process Temperature | Up to 80O°C for Neoprene, Up to 150OC for PTFE |
Electrodes | SS316, HastalloyC, Titanium, Monel |
Protection | IP67; Optional: IP68, Flameproof |
Connection | Flanged to ASA/BS/DIN/JIS |
Being ISO 9001:2008 certified company, we are engrossed in offering the excellent quality range of Digital Gas Flow Meter. Known for its digital and clear display, this meter is used for measuring volume of gases such as propane and natural gas. The provided meter is manufactured using quality-approved raw materials and cutting-edge techniques under the proper guidance of our skilled technocrats in conformance with set market quality standards. Clients can avail this Digital Gas Flow Meter in several specifications as per their needs at cost-effective prices.
Features:
Technical Details:
Parameter | CVG-MG4003 | CVG-MG4008 | Unit |
DN | 3 | 8 | mm |
Flow Rate Range | 0~2, 3, 4, 5 | 0~10, 20, 30, 40, 50 | SLPM |
Turn-down | 100:1 | ||
Accuracy | ±(1.5 + 0.2 FS) | % | |
Repeatability | 0.25 | % | |
Null Shift | ± 30 | mV | |
Output Shift | ± 0.12 | % / °C | |
Response Time | 100 (default, 10, 20, 50, 200, 100 selectable) | msec | |
Power Supply | 8~24 Vdc, 50mA | ||
Output | Linear: Analog 0.5~4.5 Vdc; RS232, RS485 | ||
Display | 4 - digit, 7-swgment LED; 2 status LED | ||
Units | Instant flow rate: SLPM; Flow accumulation: SL | ||
Display Resolution | 1.001, 0.01, 0.1 selectable | 0.01, 0.1 selectable | SLPM |
Pressure Drop | 100 | 600 | Pa |
Max. Pressure | 0.5 | MPa | |
Working Temperature | -10 ~ +55 | °C | |
Storage Temperature | -20 ~ +65 | °C |
Additional Information: